SECTION 501-11: Glass, Frames and Mechanisms
| 2014 Flex Workshop Manual
|
GENERAL PROCEDURES
| Procedure revision date: 05/02/2013
|
NOTE: Initialization is required to learn both the full UP and full DOWN positions and the profile of the glass as it travels through the glass channel. Once initialized, obstacle detection is enabled.
NOTE: A new (original factory setting) or de-initialized LH front window motor will not operate in one-touch up mode until initialized. If a new LH front window motor has been installed, proceed to the initialization procedure.
NOTE: The LH front window motor must be de-initialized, then initialized whenever the LH front window motor is removed from the window regulator assembly, a new window regulator is installed, a new window glass is installed, a new top run is installed or for any operation in which grease or lubricants are applied to the window regulator or glass run.
NOTE: If diagnosing a LH front window switch concern, carry out the window initialization procedure before installing a new window switch.
NOTE: All LH front window components (window glass, window regulator, window motor, seals and glass top run) must be installed and tightened to specification before carrying out the initialization procedure.
De-initialization procedure
Initialization procedure
NOTE: If the initialization procedure is only partially completed, the LH front window motor will remain un-initialized and will not operate in one-touch up mode.