SECTION 501-20B: Supplemental Restraint System
2014 Flex Workshop Manual
GENERAL PROCEDURES
Procedure revision date: 05/02/2013

Clockspring Adjustment

 WARNING: If the clockspring is not correctly centralized, it may fail prematurely. If in doubt, repeat the centralizing procedure. Failure to follow these instructions may increase the risk of serious personal injury or death in a crash.

NOTE: Typical SCCM and clockspring shown, others similar.

  1. NOTICE: Do not over-rotate the clockspring inner rotor. The internal ribbon wire is connected to the clockspring rotor. The internal ribbon wire acts as a stop and can be broken from its internal connection. Failure to follow this instruction may result in component damage and/or system failure.

    NOTE: After final positioning, do not allow the clockspring rotor to rotate from this position.

    1. Turn until resistance is felt, then turn clockwise so the electrical connector is in the 12 o'clock position.
    1. -