SECTION 303-13: Evaporative Emissions
2014 Flex Workshop Manual
REMOVAL AND INSTALLATION
Procedure revision date: 05/02/2013

Evaporative Emission Canister Purge Valve — 3.5L Ti-VCT

Removal and Installation

 WARNING: Do not smoke, carry lighted tobacco or have an open flame of any type when working on or near any fuel-related component. Highly flammable mixtures are always present and may be ignited. Failure to follow these instructions may result in serious personal injury.

 WARNING: Do not carry personal electronic devices such as cell phones, pagers or audio equipment of any type when working on or near any fuel-related component. Highly flammable mixtures are always present and may be ignited. Failure to follow these instructions may result in serious personal injury.

 WARNING: Always disconnect the battery ground cable at the battery when working on an evaporative emission (EVAP) system or fuel-related component. Highly flammable mixtures are always present and may be ignited. Failure to follow these instructions may result in serious personal injury.

NOTE: Removal steps in this procedure may contain installation details.

  1. Disconnect the battery ground cable. For additional information, refer to Section 414-01 .
  1. Disconnect the quick connect coupling. For additional information, refer to Section 310-00 .
  1. To install, tighten to 10 Nm (89 lb-in).
  1. To install, reverse the removal procedure.