SECTION 412-01: Climate Control
2014 Flex Workshop Manual
REMOVAL AND INSTALLATION
Procedure revision date: 05/02/2013

Blower Motor

Removal and Installation

  1. Remove the 3 RH lower instrument panel insulator screws and the RH lower instrument panel insulator.
  1. Remove the blower motor.
    1. Disconnect the blower motor electrical connector.
    1. Remove the blower motor vent tube retainer and the blower motor vent tube.
    1. Rotate the blower motor counterclockwise to detach it from the heater core and evaporator core housing.
  1. To install, reverse the removal procedure.