SECTION 412-01: Climate Control
2014 Flex Workshop Manual
REMOVAL AND INSTALLATION
Procedure revision date: 05/02/2013

Temperature Blend Door Actuator — RH

Removal and Installation

  1. Detach the glove compartment damper and lower the glove compartment.
  1. Working through the glove compartment opening, detach the instrument panel wire harness pin-type retainer from the heater core and evaporator core housing support.
  1. Remove the 2 RH temperature blend door actuator screws. Reposition the RH temperature blend door actuator to allow access to the electrical connector and disconnect the RH temperature blend door actuator electrical connector. Remove the RH temperature blend door actuator.
  1. To install, reverse the removal procedure.
  1. NOTE: The purpose of the module actuator position calibration is to allow the HVAC module to reinitialize and calibrate the actuator stop points. To carry out calibration, carry out the following steps.

    Remove Smart Junction Box (SJB) fuse 15 for at least one minute.
  1. NOTE: When the ignition switch is switched to the ON position, the HVAC module will initialize and calibrate the actuators. Calibration of the actuators will take approximately 30 seconds.

    Reinstall SJB fuse 15. Turn the ignition switch to the ON position and wait 30 seconds before verifying correct RH temperature blend door operation.