SECTION 414-05: High Voltage Converter/Power Point Inverter
2014 Flex Workshop Manual
REMOVAL AND INSTALLATION
Procedure revision date: 05/02/2013

Direct Current/Alternating Current (DC/AC) Inverter


Item Part Number Description
1 19G317 DC/AC inverter
2 Electrical connector (part of 14405)
3 DC/AC inverter bolts (3 required)

Removal and Installation

 WARNING: Disconnect the 12 volt battery before servicing the direct current to alternating current (DC-AC) inverter or alternating current (AC) powerpoint to prevent the risk of high voltage shock. Failure to follow this instruction may result in serious personal injury.

  1. Disconnect the battery. Refer to Section 414-01 .
  1. Remove the lower RH rear quarter trim panel. Refer to Section 501-05 .
  1. Disconnect the electrical connector from the DC/AC inverter.
  1. Remove the 3 bolts and the DC/AC inverter.
  1. To install, reverse the removal procedure.