SECTION 419-01B: Anti-Theft — Passive Anti-Theft System (PATS), Without Intelligent Access (IA)
| 2014 Flex Workshop Manual
|
GENERAL PROCEDURES
| Procedure revision date: 05/02/2013
|
NOTE: This procedure works only if 2 or more programmed keys are available. If 2 programmed keys are not available, refer to Key Programming Using Diagnostic Equipment .
NOTE: This procedure works only if the customer spare key programming is enabled. If the customer spare key programming is disabled, REFER to Enable or Disable Spare Key Programming or Key Programming Using Diagnostic Equipment .
NOTE: The doors lock and then unlock to confirm that each IKT is programmed.
Within 10 seconds of turning the second key to OFF, insert the new, unprogrammed PATS key into the ignition key cylinder and turn the ignition key cylinder to RUN (maintain the key in RUN for approximately 6 seconds).