Pin # | Circuit # | Color | Gauge | Function | Qualifier | Used | 1 | VH101 | WH-VT | 22 | CTRL MOD. - CLIMATE # BLOWER MOTOR CONTROL | | 1 |
2 | CH207 | BU | 26 | CTRL MOD. - CLIMATE # DOOR MOTOR RECIRC. COIL 1 / CLOSE (IF PLUS) | | 1 |
3 | CH208 | OG | 26 | CTRL MOD. - CLIMATE # DOOR MOTOR RECIRC. COIL 2 / OPEN (IF PLUS) | | 1 |
4 | | | | | | 0 |
5 | | | | | | 0 |
6 | CH228 | GY | 26 | CTRL MOD. - CLIMATE # DOOR MOTOR DEFROST COIL 1 / CLOSE (IF PLUS) | | 1 |
7 | CH229 | WH | 26 | CTRL MOD. - CLIMATE # DOOR MOTOR DEFROST COIL 2 / OPEN (IF PLUS) | | 1 |
8 | CH238 | YE | 26 | CTRL MOD. - CLIMATE # DOOR MOTOR TEMP. LEFT COIL 1 / CLOSE (IF PLUS) | | 1 |
9 | CH239 | BU | 26 | CTRL MOD. - CLIMATE # DOOR MOTOR TEMP. LEFT COIL 2 / OPEN (IF PLUS) | | 1 |
10 | GD374 | BK-WH | 20 | GROUND - TUNNEL (BC3T) | | 1 |
11 | CH123 | VT-GN | 22 | CTRL MOD. - BLOWER MOTOR RELAY | | 1 |
12 | VDB06 | GY-OG | 22 | CONNECTOR - DIAGNOSTIC # CAN BUS MEDIUM SPEED HIGH | | 1 |
13 | VDB07 | VT-OG | 22 | CONNECTOR - DIAGNOSTIC # CAN BUS MEDIUM SPEED LOW | | 1 |
14 | | | | | | 0 |
15 | | | | | | 0 |
16 | VH438 | GN | 26 | SENSOR - DOOR POSITION RECIRC. | | 1 |
17 | | | | | | 0 |
18 | | | | | | 0 |
19 | VH406 | VT-BN | 22 | SENSOR - A/C EVAPORATOR TEMPERATURE (ACET) | | 1 |
20 | VH440 | BU | 26 | SENSOR - DOOR POSITION TEMP. LEFT | | 1 |
21 | VH436 | YE | 26 | SENSOR - DOOR POSITION DEFROST | | 1 |
22 | | | | | | 0 |
23 | RH111 | GY-BU | 22 | CTRL MOD. - CLIMATE # DOOR POSITION SENSORS ALSO GENERIC VREF RETURN IN LOGICAL SCHEMATICS | | 1 |
24 | LH111 | BN | 26 | CTRL MOD. - CLIMATE # DOOR POSITION SENSORS ALSO GENERIC VREF IN LOGICAL SCHEMATICS | | 1 |
25 | CRD02 | BN-BU | 22 | CTRL MOD. - RELAY HEATER REAR WINDOW | | 1 |
26 | SBP46 | BN-RD | 22 | FUSE - 46 OR CIRCUIT BREAKER | | 1 |