SECTION 412-02: Auxiliary Climate Control
2014 Flex Workshop Manual
REMOVAL AND INSTALLATION
Procedure revision date: 05/02/2013

Thermostatic Expansion Valve


Material
Item Specification
Motorcraft® PAG Refrigerant Compressor Oil
YN-12-D
WSH-M1C231-B


Item Part Number Description
1 W520413 Auxiliary Thermostatic Expansion Valve (TXV) fitting nut
2 — Auxiliary TXV bolt (part of 19849 kit) (2 required)
3 19849 Auxiliary TXV
4 19E889 O-ring seal (4 required)

Removal and Installation

  1. Remove the auxiliary climate control housing. For additional information, refer to Auxiliary Climate Control Housing in this section.
  1. NOTICE: The auxiliary line floorpan bracket screws are loosened only to allow the auxiliary evaporator tubes to be positioned away from the auxiliary Thermostatic Expansion Valve (TXV). Do not fully disassemble the floorpan bracket or separate the floorpan gasket from the bracket. If the floorpan gasket is separated from the bracket, or if it is damaged, a new gasket must be installed to avoid noise and water leak concerns.

    Loosen the 2 auxiliary line floorpan bracket screws.
  1. Remove the auxiliary TXV fitting nut and disconnect the fitting.
  1. Remove the 2 auxiliary TXV bolts and the auxiliary TXV .
  1. To install, reverse the removal procedure.